NUMERICAL ANALYSIS OF BOVINE TRABECULAR BONE BY USING PHYSIOLOGICAL LOADS WITH SPECIFIC TO NORMAL WALKING AND DOWN STAIRS LOADS

Authors

  • Arsat Z.A Arsat Z.A Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 Johor Bahru, Johor, Malaysia.
  • Fatihhi S.J Fatihhi S.J Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia.
  • Rabiatul A.A.R Rabiatul A.A.R Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia.
  • Ardiyansyah Syahrom Sport Innovation and Technology Centre (SITC), Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia.
  • Harun M.N Harun M.N Department of Applied Mechanics and Design, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia.

Keywords:

Numerical Analysis, Trabecular Bone, Cancellous bone, multi-axial load, physiological loads.

Abstract

This study is containing of simulation on sectioned bovine trabecular bone. The aim of this research is to determine the prediction of the compressive fatigue behavior on cancellous bone specimens as a function of density, porosity and volume fraction. The specimen was extracted from fresh bovine bone with interested section dimension for about 2 × 2 × 3.5 mm. After scanned process through µCT, the bone was constructed using Mimics. With preferred size of elements and consumed time per simulation, optimum meshing yield 774,996 elements number was used. Combination of 3 axes loads for both physiological movements specific to normal walking and downstairs presented as one minute trends cycle completed during stance phase was applied on trabecular bone 3D model. Simulation was conducted with the bottom of the model fixed while gait loads applied at the top. Most deflection with highest stress occurred during downstairs simulated condition. Young modulus for normal walking and downstairs loading condition are 14.8 GPa and 14.9 GPa respectively. Differences of the compressive experimental data compared to present result could be influenced by density model. Compressive stress alone could not represent any actual physiological loads during daily activities.

References

Taylor, S.J.G., and Walker, P.S. 2001. Forces and moments telemetered from two distal femoral replacements during various activities. Journal of Biomechanics 34, 839-848.

Duda, G.N., Schneider, E., and Chao, E.Y.S. 1997. Internal forces and moments in the femur during walking. Journal of Biomechanics 30, 933-941.

Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., and Duda, G.N. 2001. Hip contact forces and gait patterns from routine activities. Journal of Biomechanics 34, 859-871.

Silva, M.J. 2007. Biomechanics of osteoporotic fractures. Injury 38, 69-76.

Greenspan, S.L., Myers, E.R., Maitland, L.A., Resnick, N.M., and Hayes, W.C. 1994. FAll severity and bone mineral density as risk factors for hip fracture in ambulatory elderly. JAMA: The Journal of the American Medical Association 271, 128-133.

Kannus, P., Sievänen, H., Palvanen, M., Järvinen ,T., and Parkkari J. 2005. Prevention of falls and consequent injuries in elderly people. Lancet 366, 1885-1893.

Kanis, J.A., Melton, L.J., Christiansen, C., Johnston, C.C., and Khaltaev, N. 1994. The diagnosis of osteoporosis. Journal of Bone and Mineral Research 9, 1137-1141.

Nagaraja, S., Lin, A.S.P., and Guldberg, R.E. 2007. Age-related changes in trabecular bone microdamage initiation. Bone 40, 973-980.

Hayes, W., Myers, E., Morris, J., Gerhart, T., Yett, H., and Lipsitz, L. 1993. Impact near the hip dominates fracture risk in elderly nursing home residents who fall. Calcified Tissue International 52, 192-198.

Pearce, A., Richards, R., Milz, S., Schneider, E., and Pearce, S. 2007. Animal models for implant biomaterial research in bone: a review. Eur Cell Mater 13, 1-10.

Kopperdahl, D.L., and Keaveny, T.M. 1998. Yield strain behavior of trabecular bone. Journal of Biomechanics 31, 601-608.

Cory, E., Nazarian, A., Entezari, V., Vartanians, V., Müller, R., and Snyder, B.D. 2010. Compressive axial mechanical properties of rat bone as functions of bone volume fraction, apparent density and micro-ct based mineral density. Journal of Biomechanics 43, 953-960.

Goldstein, S.A. 1987. The mechanical properties of trabecular bone: Dependence on anatomic location and function. Journal of Biomechanics 20, 1055-1061.

Linde, F., Hvid, I., and Madsen, F. 1992. The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens. Journal of Biomechanics 25, 359-368.

Linde, F., and Sørensen, H.C.F. 1993. The effect of different storage methods on the mechanical properties of trabecular bone. Journal of Biomechanics 26, 1249-1252.

Keaveny, T.M., Guo, X.E., Wachtel, E.F., McMahon, T.A., and Hayes, W.C. 1994. Trabecular bone exhibits fully linear elastic behavior and yields at low strains. Journal of Biomechanics 27, 1127-1136.

Keaveny, T.M., Wachtel, E.F., Guo, X.E., and Hayes, W.C. 1994. Mechanical behavior of damaged trabecular bone. Journal of Biomechanics 27, 1309-1318.

Runkle, J.C., and Pugh, J. 1975. The micro-mechanics of cancellous bone. II. Determination of the elastic modulus of individual trabeculae by a buckling analysis. Bull Hosp Joint Dis 36, 2-10.

Ashman, R.B., and Jae Young, R. 1988. Elastic modulus of trabecular bone material. Journal of Biomechanics 21, 177-181.

Hardinge, M.G. 1949. Determination of the strength of the cancellous bone in the head and neck of the femur. Surg Gynecol Obstet 89, 439-441.

Keller, T.S. 1994. Predicting the compressive mechanical behavior of bone. Journal of Biomechanics 27, 1159-1168.

Szabo, M.E., Taylor, M., and Thurner, P.J. 2011. Mechanical properties of single bovine trabeculae are unaffected by strain rate. Journal of Biomchanics 44, 962-967.

Ryan, S.D., and Williams, J.L. 1989. Tensile testing of rodlike trabeculae excised from bovine femoral bone. Journal of Biomechanics 22, 351-355.

Ducheyne, P., Heymans, L., Martens, M., Aernoudt, E., de Meester, P., and Mulier, J.C. 1977. The mechanical behaviour of intracondylar cancellous bone of the femur at different loading rates. Journal of Biomechanics 10, 747-762.

Kelly, N., and McGarry, J.P. 2012. Experimental and numerical characterisation of the elasto-plastic properties of bovine trabecular bone and a trabecular bone analogue. Journal of the Mechanical Behavior of Biomedical Materials 9, 184-197.

Gupta, A., Bayraktar, H., Fox, J., Keaveny, T., and Papadopoulos, P. 2007. Constitutive Modeling and Algorithmic Implementation of a Plasticity-like Model for Trabecular Bone Structures. Computational Mechanics 40, 61-72.

Guillen, T., Zhang, Q.H., Tozzi, G., Ohrndorf, A., Christ, H.J., and Tong, J. 2011. Compressive behaviour of bovine cancellous bone and bone analogous materials, microCT characterisation and FE analysis. Journal of the Mechanical Behavior of Biomedical Materials 4, 1452-1461.

Downloads

Published

2018-04-02

How to Cite

Arsat Z.A, A. Z., Fatihhi S.J, F. S., Rabiatul A.A.R, R. A., Syahrom, A., & Harun M.N, H. M. (2018). NUMERICAL ANALYSIS OF BOVINE TRABECULAR BONE BY USING PHYSIOLOGICAL LOADS WITH SPECIFIC TO NORMAL WALKING AND DOWN STAIRS LOADS. Jurnal Mekanikal, 35(2). Retrieved from https://jurnalmekanikal.utm.my/index.php/jurnalmekanikal/article/view/69