THE APPLICABILITY OF ISO 5151 AND ISO 8187 TEST CONDITION FOR AIR CONDITIONER AND HOUSEHOLD REFRlGERATOR IN MALAYSIA

Authors

  • Masjuki Hassan Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia
  • Indra Mahlia Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia
  • Saidur Rahman Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia
  • Imtiaz Ahmed Choudhury Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia

Keywords:

Air conditioning, refrigerator, lest conditions, test procedure, ratings.

Abstract

Malaysia is adopting the minimum energy efficiency standard for
room air conditioner and household refrigerator, therefore, the
test procedures for rating and testing must be established.
Laboratory testing and certification are the important parts of
introducing the minimum energy efficiency standard for these
appliances. The requirements for the specific country must be
clarified before setting the standard. This paper is an analysis of
the applicability of ISO 5151 and ISO 8187 air conditioner and
refrigerator test condition in Malaysia. The analysis was made
based on climatic conditions that prevail in Malaysia. Today, since
there is a trend in international harmonization of appliance
standard, this paper can be considered as a support of the
purpose. Afew internationaltest standards were also given.

References

Department of Electricity and Gas supply Malaysia Statistics of electricity supply industry in Malaysia, 1999.

Ramani, K.V., Islam, M.N. and Reddy, A.K.N. (1993), Rural energy systems in the Asia-Pacific ; Survey of their status, planning and management. APDC, Kuala Lumpur, Malaysia .

Meier, A.K., Hill, J.E.( 1997), Energy lest procedures fo r appliances. Energy and Building, 26 (1), 23-33.

Meier, A.K., (1995), Ref rigerator energy use in the laboratory and in the field. Energy and Building, 22 (1): 233-243.

Turie l, I. (1997), Present status of residential appliance energy efficiency standards-an international overview, Energy and Building, 26: 5-15.

ISO 5151. (1994), Non-ducted air conditioners and heat pumps-Testing and rating for performance, first edition, Geneva, Switzerland.

Personal communication received from Iryzhar Divinagracia, (1999), Fuels and Appliance Laboratory Philippines Department of Energy.

Dougherty B.P. (1997), Department of energy air-conditionerlheat pump test procedure update, 3rd International Conference on Heat Pump in Cold Climate, Aug 11-12, 493 - 508.

ISO 8187. (1988), Household ref rigerator-freezers-eharacteristics and test methods, Geneva, Switzerland.

ASHRAE, Equipment handbook (1988), 'Household refrigerators and freezers. 2nd edition, McGraw-Hili.

II . Kao, J.E. and Kelly, G.E., (1996), Factors affecting the energy consumption of two refrigerator/freezers. ASHRAE transaction, 102 (2).

Alissi, M.S., (1988), Effec ts of ambient temperature. ambient humidity. and door openings on energy consumption of a household refrigerat or-freezer. ASHRAE transaction, 94 (2): 1713-1736.

Gage, C.L., (1995), Field usage and its impacts on energy consumption of refrigerator/freezers. ASHRAE transaction, 101 (2): 1201-1247.

Yunus, A.C. and Michael, A.B. (1987), Thermodynamics; An engineering approach, Third edition, McGraw-Hill .

Malaysian Meteorological Service. Annual summary of meteorological observation 1972-1998, (1998). Malaysian Meteorological Service,. Kuala Lumpur.

Van-Straaten, 1. F., (1967), Thermal performance of buildings. Elsevier, Amsterdam.

Asian secretari at. (1990), The Asian users' manualfo r the Asian climatic atlas and compendium of climatic statistics. ASEAN sub committee on meteorology and geophysics Asean committee on science and technology, Jakarta.

Duffy, J., (1996 ), Energy labeling, standards and building codes: A global survey and assessment fo r selected developing countries. GEEV Publications, Washington, D.C.

Downloads

Published

2018-05-16

How to Cite

Hassan, M., Mahlia, I., Rahman, S., & Choudhury, I. A. (2018). THE APPLICABILITY OF ISO 5151 AND ISO 8187 TEST CONDITION FOR AIR CONDITIONER AND HOUSEHOLD REFRlGERATOR IN MALAYSIA. Jurnal Mekanikal, 10(2). Retrieved from https://jurnalmekanikal.utm.my/index.php/jurnalmekanikal/article/view/270

Issue

Section

Mechanical

Similar Articles

<< < 9 10 11 12 13 14 15 > >> 