EXPERIMENTAL VERIFICATION OF COLUMN AT EXTREME TEMPERATURE

Authors

  • Badri Abdul Ghani Department of Mechanics of Materials Faculty of Mechanical Engineering Universiti Teknologi Malaysia 81310 Johor Bahru, Johor
  • Mohamed El-Shayeb Department of Mechanics of Materials Faculty of Mechanical Engineering Universiti Teknologi Malaysia 81310 Johor Bahru, Johor
  • T.T.Lie T.T.Lie Division of Building Research National Research Council, Canada

Keywords:

Keywords

Abstract

Experim ental studies have been carried out to predict the fire
resistance of protected I-shaped steel insulated with ceramic
fibre. The steel section selected were W250-80 and W3IO-I58.
The experimental results are compared with those obtained using
the mathematical models develop by the same authors. The
results indicate that the model is capable ofpredicting the fire.

References

Ghani, B. A. et. ai, Heat Transfer and Strength Analysis of Column at Extreme Temperature, University Techno logy of Malaysia, 199.6.

El-S haycb, Mohamed, Fire-Resistance of Co ncrete-Filled and Rein forcedcConcrete Columns, PhD. Thesis, Universi ty o f New Hampshire, US A, May1986.

Lie, T. T. ,Temperature of Prot ected Steel in Fire, Behaviour o f Structural Steel in Fire, Ministry of Technology and Fire Offices, Committee Joint FireResearch Organisation Symposium No.2, H. M. S. 0 ., London, 1968.

Lie, T. T. Feas ibility o f Determining the Equilibrium Moi sture Condition in Fire ResistanceTest Specimens by Measuring their Elec trical-res is tance, BuildingResearch Note No. 75, Division of Building Research, NRC, Ottawa, 1971 .

Dusinberre, G. M. Heat Transfer Calculations by Finite Differences, Int ernation al Textbook Company, Scranton, Pennsylvania, 1961.

Harrnathy, T. Z. A Treatise on Theo retical Fire Endurance Rating, American Society for Test ing Materials , Special Technical Publication No. 301, 1961 , pp. 10-40.

Harrnathy T. Z. and Lie T. T., Experimental Verification of the Rule of Moisture Mom ent , Fire Technology, Vol. 7, 1964 p. 17.

Bibliography Bardell , Kathleen . Spray-Applied Fire Resistive Coatings for Steel Building Columns, Fire Resistive Coatings: The Need For Standards, ASTM STP 826 Morris Lieff and F.M . Stumpf, cds., American Society for Testing and Materials, 1983,40-55.

Standard Meth od s o f Mire Tests of Building Construction and Materials, ASTM Designation E I 19-69, 1969 Book of ASTM Standards, Part 14, pp, 436-452.

Brit, Iron Steel Res. Assoc., Physical Co nstants o f Som e Commercial Steels at Elevated Temperatu re, Butterw orths Sci . Publ. , London, 1953.

Fujii , S. The Theoretical Calculation o f Temperature-rise o f Thermally Protected Steel Column Exposed to the Fire, Building Research Institute Occasional Report No . 10, Tokyo, 196 3.

Emmo ns H. W., The Numerical Solution of Heat Conductio n Problems, Transactions of the Ame rican Society of Mech ani cal Engi neers , Vol. 65, 1943, pp . 607-6 15.

Thrinks W. and Mawhinn ey M. W., Industri al Furnaces, John Wiley and Sons, Inc ., New York, 1986

Law, M., Structural Fire Protection in the Process Industry Building, Vol. 216, No. 29, 1969, pp. 86-90.

Rains W.A ., Evaluation on Existing Fire Protection Materials, Phase I Report, Presented to th e American Iron and steel Institute Fire Technology Subcommittee, 1973 .

Stumpf Frank M., Spray-Applied Fibrou s Materials and Fire Resi stive Coatings, Presented to the ASTM, 1984.

Downloads